Customization: | Available |
---|---|
Type: | Mr or Mrl |
Load Capacity: | 320-5000kgs |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PART NO |
ITEM |
SPECIFICATION |
I |
Mechanical Parts |
|
1.1 |
Traction Machine |
VVVF Geared Machine or PM Gearless Machine |
1.2 |
Traction Machine Bed Set |
Made for the replaced Traction Machine |
1.3 |
Speed Governor |
Nova Standard |
1.4 |
Pulley Sheave |
For above traction machine |
1.5 |
Wire Rope |
For above traction machine & speed governor |
1.6 |
VVVF Door Operator |
Replace the existing old door system |
1.7 |
Landing Door System |
|
II |
Electrical Parts |
|
2.1 |
Complete Control Cabinet |
VVVF in Serial or Parallel system, 2.2-37 KW, 220V/380V |
2.2 |
Encorder with Cable |
Installed in the Traction Machine |
2.3 |
Car Top Board |
Installed in the Car Top Inspection Box. |
2.4 |
Display Board for COP and LOPs |
Installed in the COP and LOPs. |
2.5 |
Car Instruction Board |
Installed in the COP. |
2.6 |
COP |
You may visit our website to choose the model you need: http://novaelevator.en.made-in-china.com |
2.7 |
LOPs |
|
2.8 |
Car Top Inspection Box |
NOVA Standard |
.9 |
Pit box |
NOVA Standard |
2.10 |
Leveling Photoelectric Switch |
DC24V Normally Open |
2.11 |
Limit Switch |
Normally Close |
2.12 |
All Cable |
|
2.12.1 |
Traveling Cable |
From Control Cabinet to Car top Inspection Box. |
2.12.2 |
Round Shaft Cable |
From Control Cabinet to Limit Siwtchs. |
2.12.3 |
Round Shaft Cable |
From Control Cabinet to Pit Switch |
2.12.4 |
Landing Door Lock Cable |
From Control Cabinet to Landing Door Locks. |
2.12.5 |
LOP Communication Cable |
From Control Cabinet to LOPs. |
2.12.6 |
Car Top Branch Cables |
From Car Top Inspection Box to COP, Door Operator, Light Curtain and so on |
III |
Other Opitional Parts |
|
3.1 |
Group Controlling Board |
For 3-8 units lift |
3.2 |
PC Monitoring Board |
Quarter Monitoring |
3.3 |
ARD |
Match to Control Cabinet |
3.4 |
UPS |
Emergency Power for Brake |
3.5 |
IC Card |
Installed in the COP and LOPs. |
3.6 |
Voice Announcement |
Broadcast to the floor information |
3.7 |
Vice COP |
For run-through door |